Exos E 4U106 Features: Scale your data centre with this very high density storage platform Minimise a data centre’s footprint and power consumption while maximising storage space Eliminate efficiency-draining acoustic interference with the proprietary noise attenuator Maintain your data centre easily with toolless drive carriers that save hours of time Ensure data is constantly available with hot-swappable controllers, PSUs, system fan modules, drives, and expander cards Specifications: General Max TB Per Chassis 2332 TB, Using Qty 106, 22 TB 3.5” SAS Drives Redundant Path Yes (SAS only) Host/Expansion I/O Ports Four ×4 mini-SAS HD Expansion I/O connectors per I/O module Management/Status Reporting In-band SCSI Enclosure Services Device Support SAS and SATA device support, up to 2.5 PB raw capacity with 24 TB SAS drives Max Drives per Enclosure 106 (for a full list of supported drives, please contact your account or sales manager) Hot-Swappable Components Hard drives, power supply units (PSUs), cooling modules, side-plane expanders, and I/O modules Physical Height (with top cover): 176.4 mm/6.95 in | Width (without ears and rails): 441 mm/17.4 in | Depth (with handles, without cables): 1139 mm/44.8 in | Weight 45 kg / 99 lb | Weight (with drives): 141 kg/310 lb Power Requirements Input Power Requirements 200VAC-240VAC, 50Hz/60Hz Max Power Output per PSU 2000W Environmental/Temperature Ranges Operating/Non-operating Altitude –100 m to 3,000 m (–330 ft to 10,000 ft) / –100 m to 12,192 m (–330 ft to 40,000 ft) Operating/Non-operating Temperature ASHRAE A2, 5°C to 35°C (41°F to 95°F) derate 1°C for every 300m above 900m / –40°C to +70°C (–40°F to +158°F) Operating/Non-operating Humidity –12°C DP and 8% RH to 21°C DP and 80% RH, Max DP 21°C, Max rate of change (°C/hr): 5/20/5% to 100% non-condensing Operating/Non-operating Shock2 3 Gs, 11 ms (per axis) / 15 Gs, 7 ms, 10 shock pulse Operating/Non-operating Vibration3 0.18 Gs rms, 5Hz to 500Hz, 30 min per axis / 0.54 Gs rms (in Z) 0.25 Gs rms (in X & Y), 6Hz to 200Hz Standards/Approvals Standard Marks/Approvals United States, Canada, European Union (EU), Australia/New Zealand, Japan, China (PRC), Russia, Mexico, Germany, South Korea, Taiwan, India Safety Certifications UL 62368-1 | CAN/CSA-C22.2 No.62368-1- 19 | CE to EN 62368-1 | Emissions (EMC) CB IEC 62368-1 | Power Supplies CCC & BIS Harmonics & Flicker FCC CFR 47 Part 15 Subpart B Class A | ICES/NMB-003 Class A | EN 55032:2015 Class A |AS/NZS CISPR 22/CISPR 32 Class A | VCCI Class A | KN 32/KN 35 Class A | CNS 15936 Class A Immunity EN 61000-3-2 | EN 61000-3-3 Environmental Standards EN 55032 | KN 32/KN 35 Redundant Power Supply Units Power Supply Ecodesign (Model 700-014575-0800) – Platinum Power efficiency: 230VAC50/Hz; 10% Load = >80%; 20% Load = >90%; 50% Load = >94%; 100% Load = >91% Power factor conditions (PFC): 50% Loading = >0.90 Power Supply Ecodesign (Model SPASGAT-02) – Titanium Power Efficiency: 230VAC50/Hz; 10% Load = >90%; 20% Load = >94%; 50% Load = >96%; 100% Load = >91% Power factor conditions (PFC): 50% Loading = >0.95