C3K-PWR-750WAC Power Specifications Maximum output power C3K-PWR-1150WAC: 1150 WC3K-PWR-750WAC: 750 WC3K-PWR-265WAC: 265 W Input voltage range and frequency C3K-PWR-750WAC: 750 W, C3K-PWR-265WAC: 265 W,100 to 240 VAC (autoranging), 47 to 63 Hz C3K-PWR-1150WAC: 1150 W:115 to 240 VAC (autoranging) 47 to 63 Hz Input current C3K-PWR-1150WAC:12-6 AC3K-PWR-750WAC: 10-5 AC3K-PWR-265WAC: 5-2.5 A Output ratings C3K-PWR-1150WAC: 12 V@25 A, -52 V @ 16.4 AC3K-PWR-750WAC: 12 V@25 A, -52 V @ 8.75 AC3K-PWR-265WAC: 12 V@22 A Total input BTU 1 C3K-PWR-1150WAC: 4778 Btus per hour, 1386 WC3K-PWR-750WAC: 3043 Btus per hour, 882 WC3K-PWR-265WAC: 1142 Btus per hour, 331 W Total output BTU1 C3K-PWR-1150WAC: 3939 Btus per hour, 1150 WC3K-PWR-750WAC: 2568 Btus per hour, 765 WC3K-PWR-265WAC: 907 Btus per hour, 265 W DC input voltage for RPS 2300 +12 V@25 A, 52 V@16.4 A 1 The Total input and Total output BTU ratings refer to input power into the power supply and output power from the power supply that is input into the switch.